Power Solutions

Our airfield power systems are the result of forty years of designing, engineering, implementing and commissioning airfield lighting power and control systems at facilities worldwide. Liberty's family of power systems define next-generation industry solutions, ensuring the reliable supply, control and monitoring of power for airfield lighting. Liberty has set a new standard in performance, ease of maintenance and personnel safety, while providing airport operations the flexibility to choose custom-configured systems to match specific control and monitoring requirements.

L-828/L-829 Constant Current Regulators (CCR)

Liberty manufacturers a full complement of thyristor and ferroresonant style regulators with output ratings from 1KW to 30KW, 6.6A or 20A, and input voltages from 208V to 2400V. Regulators are digitally controlled, Ethernet enabled and available in standalone or switchgear configurations.

Freedom Series Ferroresonant CCR
Freedom Series Thyristor CCR
Freedom Series 2400V Ferroresonant CCR
Freedom Series 2400V Thyristor CCR
Spirit Series Ferroresonant CCR
Spirit Series Thyristor CCR

L-847 Circuit Selector Switches

Our circuit selector switches use the latest 5KV vacuum technology to switch the output of a CCR into multiple circuits. Up to 6 circuit selectors can be provided per enclosure and are available in standalone or switchgear configurations.

Freedom Series L-847 Circuit Selector
Spirit Series L-847 Circuit Selector

PAPI Heater

To ensure that the correct visual information is provided by the PAPI, it is necessary to prevent frost or condensation from forming on the lenses or front glass of the PAPI units. The Spirit Series™ family of PAPI Heaters are designed to help eliminate this potential problem.

Spirit Series PAPI Heater

Field Circuit Cutout

The Airfield Lighting Safety Cutout (ALSC) is used to isolate the field circuit from the constant current regulator (CCR) for testing or maintenance. The ALSC consists of a base unit and a series of removable handles that provide a convenient means of testing the field circuit without disconnecting the field cables from the CCR.

Freedom Series ALSC Safety Cutout

System Upgrades

Legacy constant current regulators and circuit selectors can be upgraded, bringing technology to current standards while incorporating support for new features and capabilities. Upgrades can be implemented on an individual basis as funds are available, while minimizing disruption to airport operations.

Freedom Series Digital Control Upgrade
Spirit Series MGL Vacuum Retrofit

Accessories

Accessories have been developed to help with maintenance and troubleshooting. These include the resistive load bank tester for testing CCRs and the power lift for removal of switchgear CCR powerpacks. If you have a need for other accessories, please don’t hesitate to call. We may already have a product or can design one for you.

Freedom Series Resistive Load Bank Tester
Freedom Series Power Lift